CFDQY - 136 5113 KODAK CINEFLURE FIXER/REPLENISHER, WORKING SOLUTION

  • MSDS: CFDQY
  • Manufacturer: EASTMAN KODAK
  • Product Name: 136 5113 KODAK CINEFLURE FIXER/REPLENISHER, WORKING SOLUTION
  • National Stock Number: 6525-00D006045
Product Identification

Product ID:136 5113 KODAK CINEFLURE FIXER/REPLENISHER, WORKING SOLUTION
MSDS Date:02/07/1996
FSC:6525
NIIN:00D006045
Kit Part:Y
MSDS Number: CFDQY

Responsible Party
EASTMAN KODAK
RODCHESTER, NY 14650
US

Emergency Phone: 716-722-5151/800-242-2424

Info Phone: 716-722-5151/800-242-2424

Cage: 5K871

Contractor
EASTMAN KODAK CO US CUSTOMER SERVICE/GOVERNMENT SALES
ROCHESTER, NY 14650-3129 US

Telephone: 800-828-6203

Cage: 5K871

Ingredients

NO INGREDIENT FOR THIS FORMULATION_INGREDIENT

Hazards

Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION-EXPECTED TO BE A LOW HAZARD
FOR RECOMMENDED HANDLING. EYES-NO SPECIFIC HAZARD KNOWN. MAY CAUSE
TRANSIENT IRRITATION. SKIN-LOW HAZARD FOR RECOMMENDED HANDLING.
INGESTION-EXPECTED TO BE A LOW INGESTION HAZARD.
Explanation of Carcinogenicity:NOT CARCINOGENIC.
Effects of Overexposure:NONE SPECIFIED BY MANUFACTURER.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHALATION-IF SYMPTOMATIC, MOVE TO FRESH AIR. GET MEDICAL
ATTENTION IF SYMPTOMS OCCUR. EYES-ANY MATERIAL THAT CONTACTS THE
EYE SHOULD BE WASHED OUT IMMEDIATELY WITH WATER. GET MEDICAL
ATTENTION IF SYM PTOMS OCCUR. SKIN-WASH WITH SOAP AND WATER. GET
MEDICAL ATTENTION IF SYMPTOMS OCCUR. INGESTION-DRINK 1-2 GLASSES OF
WATER. SEEK MEDICAL ATTENTION. NEVER GIVE ANYTHING BY MOUTH TO AN
UNCONSCIOUS PERSON

Fire Fighting

Flash Point:NONE
Extinguishing Media:USE APPROPIATE AGENT FOR ADJACENT FIRE.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND
PROTECTIVE CLOTHING. FIRE OR EXCESSIVE HEAT MAY PRODUCE HAZARDOUS
DECOMPOSITION PRODUCTS.
Unusual Fire/Explosion Hazard:NONE.

Accidental Release

Spill Release Procedures:MAY REQUIRE NEUTRALIZATION IF PH<2 OR >12.5.
FLUSH TO SEWER WITH LARGE AMOUNTS OF WATER. OTHERWISE, ABSORB SPILL
WITH VERMICULITE OR OTHER INERT MATERIAL, THEN PLACE IN A CONTAINER
FOR CHEMICAL WASTE. CLEAN SURFACE THOROUGHLY TO REMOVE
CONTAMINATION.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP CONTAINER TIGHTLY CLOSED. KKEP
AWAY FROM INCOMPATIBLE SUBSTANCES.
Other Precautions:USE WITH ADEQUATE VENTILATION. WASH THOROUGHLY AFTER
HANDLING.

Exposure Controls

Respiratory Protection:NONE SHOULD BE NEEDED.
Ventilation:GOOD GENERAL VENTILATION (TYPICALLY 10 AIR CHANGES/HR)
SHOULD BE USED. VENTILATION RATES SHOULD BE MATCHED TO CONDITIONS
Protective Gloves:IMPERVIOUS GLOVES SHOULD BE WORN.
Eye Protection:WEAR SAFETY GLASSES WITH SIDE SHIELDS.
Other Protective Equipment:IT IS A GOOD INDUSTRIAL HYGIENE PRACTICE TO
MINIMIZE SKIN CONTACT.
Work Hygienic Practices:EYE BATH, WASHING FACILITIES, SAFETY SHOWERS.
WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
THIS IA THE WORKING SOLUTION OF THE KIT.

Chemical Properties

HCC:N1
Boiling Pt:B.P. Text:>212F,>100C
Vapor Pres:18 MMHG
Vapor Density:0.6
Spec Gravity:1.094
pH:4.4
Solubility in Water:COMPLETE
Appearance and Odor:LIQUID, COLORLESS, SLIGHT ODOR.
Percent Volatiles by Volume:80-90

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGNETS, BASE, STRONG ACIDS, SODIUM HYPOCHLORITE
(BLEACH).
Stability Condition to Avoid:STABLE.
Hazardous Decomposition Products:AMMONIA, CHLORAMINE, OXIDES OF
NITROGEN, OXIDES OF SULFUR.

Disposal

Waste Disposal Methods:DISCHARGE, TREATMENT OR DISPOSAL IS SUBJECT TO
NATIONAL, STATE OR LOCAL LAWS. FLUSH TO SEWER WITH LARGE AMOUNTS OF
WATER.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.